Monday, June 22, 2015

Cisco 3750x FRULink 10G service module in pass-thru mode

%PLATFORM_SM10G-3-SW_VERSION_MISMATCH: The FRULink 10G Service Module (C3KX-SM-10G) in switch 1 has a software version that is incompatible with the IOS software version. Please update the software. Module is in pass-thru mode.

Switch#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------
 1       OK               75C/74C         ver-mismatch  03.00.65
 2       OK               69C/70C         ver-mismatch  03.00.65

Switch#archive download-sw flash:c3kx-sm10g-tar.150-2.SE7.tar
examining image...
extracting info (100 bytes)
extracting c3kx-sm10g-mz.150-2.SE7/info (499 bytes)
extracting info (100 bytes)

Stacking Version Number: 1.49

System Type:             0x00010002
  Ios Image File Size:   0x017BDA00
  Total Image File Size: 0x017BDA00
  Minimum Dram required: 0x08000000
  Image Suffix:          sm10g-150-2.SE7
  Image Directory:       c3kx-sm10g-mz.150-2.SE7
  Image Name:            c3kx-sm10g-mz.150-2.SE7.bin
  Image Feature:         IP|LAYER_3|MIN_DRAM_MEG=128
  FRU Module Version:    03.00.78


Updating FRU Module on switch 1...
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Updating FRU FPGA image...

FPGA image update complete.

Updating FRU Module on switch 2...
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
All software images installed.

Switch#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------
 1       OK               75C/74C         ver-mismatch  03.00.65
 2       OK               69C/70C         ver-mismatch  03.00.65


Switch#switch 1 frulink reload
This will cause the FRULink's traffic and links to be disrupted. Are you sure? (yes/[no]): yes
FRULink on Switch 1 reloaded.
TPB-12thFl-3750x#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------
 1       OK               73C/73C         connected     03.00.78
 2       OK               71C/70C         ver-mismatch  03.00.65


Switch#switch 2 frulink reload
This will cause the FRULink's traffic and links to be disrupted. Are you sure? (yes/[no]): yes
FRULink on Switch 2 reloaded.
TPB-12thFl-3750x#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------

Switch#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------
 1       OK               73C/73C         connected     03.00.78
 2       OK               71C/70C         notconnected  N/A

TPB-12thFl-3750x#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------
 1       OK               73C/73C         connected     03.00.78
 2       OK               71C/71C         checking-ver  N/A


TPB-12thFl-3750x#sh switch service-modules
Switch/Stack supports service module CPU version: 03.00.78
                          Temperature                     CPU
Switch#  H/W Status       (CPU/FPGA)      CPU Link      Version
-----------------------------------------------------------------
 1       OK               73C/73C         connected     03.00.78
 2       OK               69C/71C         connected     03.00.78

No comments: